new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Jun 3

Metal artefact reduction sequences for a piezoelectric bone conduction implant using a realistic head phantom in MRI

Industry standards require medical device manufacturers to perform implant-induced artefact testing in phantoms at a pre-clinical stage to define the extent of artefacts that can be expected during MRI. Once a device is commercially available, studies on volunteers, cadavers or patients are performed to investigate implant-induced artefacts and artefact reduction methods more in-depth. This study describes the design and evaluation of a realistic head phantom for pre-clinical implant-induced artefact testing in a relevant environment. A case study is performed where a state-of-the-art piezoelectric bone conduction implant is used in the 1.5 T and 3 T MRI environments. Images were acquired using clinical and novel metal artefact reducing (MARS) sequences at both field strengths. Artefact width and length were measured in a healthy volunteer and compared with artefact sizes obtained in the phantom. Artefact sizes are reported that are similar in shape between the phantom and a volunteer, yet with dimensions differing up to 20% between both. When the implant magnet is removed, the artefact size can be reduced below a diameter of 5 cm, whilst the presence of an implant magnet and splint creates higher artefacts up to 20 cm in diameter. Pulse sequences have been altered to reduce the scan time up to 7 minutes, while preserving the image quality. These results show that the anthropomorphic phantom can be used at a preclinical stage to provide clinically relevant images, illustrating the impact of the artefact on important brain structures.

  • 5 authors
·
Jun 6, 2023

Learning to Predict Structural Vibrations

In mechanical structures like airplanes, cars and houses, noise is generated and transmitted through vibrations. To take measures to reduce this noise, vibrations need to be simulated with expensive numerical computations. Deep learning surrogate models present a promising alternative to classical numerical simulations as they can be evaluated magnitudes faster, while trading-off accuracy. To quantify such trade-offs systematically and foster the development of methods, we present a benchmark on the task of predicting the vibration of harmonically excited plates. The benchmark features a total of 12,000 plate geometries with varying forms of beadings, material, boundary conditions, load position and sizes with associated numerical solutions. To address the benchmark task, we propose a new network architecture, named Frequency-Query Operator, which predicts vibration patterns of plate geometries given a specific excitation frequency. Applying principles from operator learning and implicit models for shape encoding, our approach effectively addresses the prediction of highly variable frequency response functions occurring in dynamic systems. To quantify the prediction quality, we introduce a set of evaluation metrics and evaluate the method on our vibrating-plates benchmark. Our method outperforms DeepONets, Fourier Neural Operators and more traditional neural network architectures and can be used for design optimization. Code, dataset and visualizations: https://github.com/ecker-lab/Learning_Vibrating_Plates

  • 5 authors
·
Oct 9, 2023

Tensegrity crutches with compliance from a pre-stressed self-tensile module improve ground reaction force profiles, speed, effort, comfort, and perceived stability

Purpose: Six million people use crutches as mobile aids in the US. Rigid designs with no axial mobility limit sensory feedback and lead to secondary injury on the upper joints. Spring-loaded designs offer compliance but may compromise stability. We designed a biologically inspired tensegrity crutch with a compliant module aiming to achieve favorable mechanical properties. The terminal module was a pre-stressed self-tensile two-cell tensegrity structure. We compared the tensegrity crutch to commercial rigid and spring-loaded crutches in mechanical tests using axial loading, in overground straight and turning walking, and in participant experience. Methods: In human trials, healthy young adults (N=18) with no recent lower-body injury performed straight walking and turning trials at a comfortable self-selected pace. A knee blocker simulated unilateral injury of the dominant leg. After using each type of crutch, participants reported their perceived levels of effort, comfort, pain, stability, and usability. Results: Compared to the rigid design, both spring-loaded and tensegrity conditions reduced peak loading rates. The tensegrity design improved effort, comfort, pain, and usability. Spring-loaded crutches reduced perceived stability and walking speed. Conclusion: The biologically inspired tensegrity crutches were an overall improvement to existing designs. Simulations and mechanical testing suggest that nonlinear stiffness, ground-following, and force feedback are among the beneficial mechanical properties that underlie this improvement.

  • 6 authors
·
May 3

A Computational Optimisation Study of Hip Implant Using Density Mapping Functionally Graded Biomimetic TPMS-based Lattice Structures

This study presents a computational optimisation framework of a hip implant through the development of a functionally graded biomimetic lattice structure, whose design was structurally optimised to limit stress shielding. The optimisation technique was inspired by the inverse of a bone remodelling algorithm, promoting an even stress distribution throughout the design region, by reducing the density and consequently the stiffness, in regions where strain energy was higher than the reference level. The result of the optimisation technique provided a non-uniform graded density distribution field that showed lower density level on the sides of the implant stem, and higher material density around the medial axis of the stem. The optimised material distribution was captured using mapping of a triply periodic minimal surface lattice structure on the implant, which resulted in porous lattice surfaces inside the solid implant. The performance of the porous implant design was evaluated through implementation of a finite element bone remodelling algorithm and comparing the bone response with a femur with fully solid implant model, in terms of stress distribution and mass change. The results of the analysis showed improved bone formation on the bone-implant interface, and enhanced stress transmission to the surrounding bone from the implant.

  • 4 authors
·
Aug 11, 2025

ConvNets for Counting: Object Detection of Transient Phenomena in Steelpan Drums

We train an object detector built from convolutional neural networks to count interference fringes in elliptical antinode regions in frames of high-speed video recordings of transient oscillations in Caribbean steelpan drums illuminated by electronic speckle pattern interferometry (ESPI). The annotations provided by our model aim to contribute to the understanding of time-dependent behavior in such drums by tracking the development of sympathetic vibration modes. The system is trained on a dataset of crowdsourced human-annotated images obtained from the Zooniverse Steelpan Vibrations Project. Due to the small number of human-annotated images and the ambiguity of the annotation task, we also evaluate the model on a large corpus of synthetic images whose properties have been matched to the real images by style transfer using a Generative Adversarial Network. Applying the model to thousands of unlabeled video frames, we measure oscillations consistent with audio recordings of these drum strikes. One unanticipated result is that sympathetic oscillations of higher-octave notes significantly precede the rise in sound intensity of the corresponding second harmonic tones; the mechanism responsible for this remains unidentified. This paper primarily concerns the development of the predictive model; further exploration of the steelpan images and deeper physical insights await its further application.

  • 2 authors
·
Jan 31, 2021

TexSenseGAN: A User-Guided System for Optimizing Texture-Related Vibrotactile Feedback Using Generative Adversarial Network

Vibration rendering is essential for creating realistic tactile experiences in human-virtual object interactions, such as in video game controllers and VR devices. By dynamically adjusting vibration parameters based on user actions, these systems can convey spatial features and contribute to texture representation. However, generating arbitrary vibrations to replicate real-world material textures is challenging due to the large parameter space. This study proposes a human-in-the-loop vibration generation model based on user preferences. To enable users to easily control the generation of vibration samples with large parameter spaces, we introduced an optimization model based on Differential Subspace Search (DSS) and Generative Adversarial Network (GAN). With DSS, users can employ a one-dimensional slider to easily modify the high-dimensional latent space to ensure that the GAN can generate desired vibrations. We trained the generative model using an open dataset of tactile vibration data and selected five types of vibrations as target samples for the generation experiment. Extensive user experiments were conducted using the generated and real samples. The results indicated that our system could generate distinguishable samples that matched the target characteristics. Moreover, we established a correlation between subjects' ability to distinguish real samples and their ability to distinguish generated samples.

  • 4 authors
·
Jul 16, 2024

TinyMyo: a Tiny Foundation Model for Flexible EMG Signal Processing at the Edge

Surface electromyography (EMG) is a non-invasive sensing modality used in several domains, including biomechanics, rehabilitation, prosthetic control, and emerging human-machine interaction paradigms. Despite decades of use, significant challenges remain in achieving robust generalization across subjects, recording systems, and acquisition protocols. To tackle these challenges, foundation models (FMs) are gaining traction when targeting end-to-end applications based on EMG signals. Yet, existing EMG FMs remain limited to single downstream tasks and lack deployability on embedded platforms. In this work, we present TinyMyo, a lightweight FM based on a Transformer encoder architecture. The model is pre-trained in a self-supervised manner on publicly available datasets and achieves high reconstruction fidelity with only 3.6M parameters. With minimal task-specific head adaptations, the same backbone is used to tackle multiple downstream tasks, leveraging datasets acquired from diverse sensing locations and hardware platforms. We demonstrate generalization across hand gesture classification, hand kinematic regression, speech production and recognition, with performance comparable to or surpassing the state of the art (SoA), and model size below 5M parameters. We achieve SoA results compared to previous FM-based works on the NinaPro DB5 (89.4pm0.16%), UCI-EMG (97.56pm0.32%), and EPN-612 (96.74pm0.09%) datasets. We report, to the best of our knowledge, the first deployment of an EMG FM on an ultra-low-power microcontroller (GAP9), achieving an average power envelope of 36.45mW. By open-sourcing the pre-trained and the downstream task architectures (https://github.com/pulp-bio/BioFoundation), we aim to provide a flexible resource that can accelerate future research and serve as a common foundation for the EMG community.

PulpBio Pulp Platform Bio
·
Dec 5, 2025

Towards a Universal Vibration Analysis Dataset: A Framework for Transfer Learning in Predictive Maintenance and Structural Health Monitoring

ImageNet has become a reputable resource for transfer learning, allowing the development of efficient ML models with reduced training time and data requirements. However, vibration analysis in predictive maintenance, structural health monitoring, and fault diagnosis, lacks a comparable large-scale, annotated dataset to facilitate similar advancements. To address this, a dataset framework is proposed that begins with bearing vibration data as an initial step towards creating a universal dataset for vibration-based spectrogram analysis for all machinery. The initial framework includes a collection of bearing vibration signals from various publicly available datasets. To demonstrate the advantages of this framework, experiments were conducted using a deep learning architecture, showing improvements in model performance when pre-trained on bearing vibration data and fine-tuned on a smaller, domain-specific dataset. These findings highlight the potential to parallel the success of ImageNet in visual computing but for vibration analysis. For future work, this research will include a broader range of vibration signals from multiple types of machinery, emphasizing spectrogram-based representations of the data. Each sample will be labeled according to machinery type, operational status, and the presence or type of faults, ensuring its utility for supervised and unsupervised learning tasks. Additionally, a framework for data preprocessing, feature extraction, and model training specific to vibration data will be developed. This framework will standardize methodologies across the research community, allowing for collaboration and accelerating progress in predictive maintenance, structural health monitoring, and related fields. By mirroring the success of ImageNet in visual computing, this dataset has the potential to improve the development of intelligent systems in industrial applications.

  • 8 authors
·
Apr 15, 2025

Comparison of Clustering Algorithms for Statistical Features of Vibration Data Sets

Vibration-based condition monitoring systems are receiving increasing attention due to their ability to accurately identify different conditions by capturing dynamic features over a broad frequency range. However, there is little research on clustering approaches in vibration data and the resulting solutions are often optimized for a single data set. In this work, we present an extensive comparison of the clustering algorithms K-means clustering, OPTICS, and Gaussian mixture model clustering (GMM) applied to statistical features extracted from the time and frequency domains of vibration data sets. Furthermore, we investigate the influence of feature combinations, feature selection using principal component analysis (PCA), and the specified number of clusters on the performance of the clustering algorithms. We conducted this comparison in terms of a grid search using three different benchmark data sets. Our work showed that averaging (Mean, Median) and variance-based features (Standard Deviation, Interquartile Range) performed significantly better than shape-based features (Skewness, Kurtosis). In addition, K-means outperformed GMM slightly for these data sets, whereas OPTICS performed significantly worse. We were also able to show that feature combinations as well as PCA feature selection did not result in any significant performance improvements. With an increase in the specified number of clusters, clustering algorithms performed better, although there were some specific algorithmic restrictions.

  • 4 authors
·
May 11, 2023

Dynamic Modeling and Vibration Analysis of Large Deployable Mesh Reflectors

Large deployable mesh reflectors are essential for space applications, providing precise reflecting surfaces for high-gain antennas used in satellite communications, Earth observation, and deep-space missions. During on-orbit missions, active shape adjustment and attitude control are crucial for maintaining surface accuracy and proper orientation for these reflectors, ensuring optimal performance. Preventing resonance through thorough dynamic modeling and vibration analysis is vital to avoid structural damage and ensure stability and reliability. Existing dynamic modeling approaches, such as wave and finite element methods, often fail to accurately predict dynamic responses due to the limited capability of handling three-dimensional reflectors or the oversimplification of cable members of a reflector. This paper proposes the Cartesian spatial discretization method for dynamic modeling and vibration analysis of cable-network structures in large deployable mesh reflectors. This method defines cable member positions as a summation of internal and boundary-induced terms within a global Cartesian coordinate system. Numerical simulation on a two-dimensional cable-network structure and a center-feed mesh reflector demonstrates the superiority of the proposed method over traditional approaches, highlighting its accuracy and versatility, and establishing it as a robust tool for analyzing three-dimensional complex reflector configurations.

  • 5 authors
·
Oct 23, 2024

BS-Diff: Effective Bone Suppression Using Conditional Diffusion Models from Chest X-Ray Images

Chest X-rays (CXRs) are commonly utilized as a low-dose modality for lung screening. Nonetheless, the efficacy of CXRs is somewhat impeded, given that approximately 75% of the lung area overlaps with bone, which in turn hampers the detection and diagnosis of diseases. As a remedial measure, bone suppression techniques have been introduced. The current dual-energy subtraction imaging technique in the clinic requires costly equipment and subjects being exposed to high radiation. To circumvent these issues, deep learning-based image generation algorithms have been proposed. However, existing methods fall short in terms of producing high-quality images and capturing texture details, particularly with pulmonary vessels. To address these issues, this paper proposes a new bone suppression framework, termed BS-Diff, that comprises a conditional diffusion model equipped with a U-Net architecture and a simple enhancement module to incorporate an autoencoder. Our proposed network cannot only generate soft tissue images with a high bone suppression rate but also possesses the capability to capture fine image details. Additionally, we compiled the largest dataset since 2010, including data from 120 patients with high-definition, high-resolution paired CXRs and soft tissue images collected by our affiliated hospital. Extensive experiments, comparative analyses, ablation studies, and clinical evaluations indicate that the proposed BS-Diff outperforms several bone-suppression models across multiple metrics. Our code can be accessed at https://github.com/Benny0323/BS-Diff.

  • 11 authors
·
Nov 26, 2023

OrthoDiffusion: A Generalizable Multi-Task Diffusion Foundation Model for Musculoskeletal MRI Interpretation

Musculoskeletal disorders represent a significant global health burden and are a leading cause of disability worldwide. While MRI is essential for accurate diagnosis, its interpretation remains exceptionally challenging. Radiologists must identify multiple potential abnormalities within complex anatomical structures across different imaging planes, a process that requires significant expertise and is prone to variability. We developed OrthoDiffusion, a unified diffusion-based foundation model designed for multi-task musculoskeletal MRI interpretation. The framework utilizes three orientation-specific 3D diffusion models, pre-trained in a self-supervised manner on 15,948 unlabeled knee MRI scans, to learn robust anatomical features from sagittal, coronal, and axial views. These view-specific representations are integrated to support diverse clinical tasks, including anatomical segmentation and multi-label diagnosis. Our evaluation demonstrates that OrthoDiffusion achieves excellent performance in the segmentation of 11 knee structures and the detection of 8 knee abnormalities. The model exhibited remarkable robustness across different clinical centers and MRI field strengths, consistently outperforming traditional supervised models. Notably, in settings where labeled data was scarce, OrthoDiffusion maintained high diagnostic precision using only 10\% of training labels. Furthermore, the anatomical representations learned from knee imaging proved highly transferable to other joints, achieving strong diagnostic performance across 11 diseases of the ankle and shoulder. These findings suggest that diffusion-based foundation models can serve as a unified platform for multi-disease diagnosis and anatomical segmentation, potentially improving the efficiency and accuracy of musculoskeletal MRI interpretation in real-world clinical workflows.

  • 11 authors
·
Feb 23

BearLLM: A Prior Knowledge-Enhanced Bearing Health Management Framework with Unified Vibration Signal Representation

We propose a bearing health management framework leveraging large language models (BearLLM), a novel multimodal model that unifies multiple bearing-related tasks by processing user prompts and vibration signals. Specifically, we introduce a prior knowledge-enhanced unified vibration signal representation to handle various working conditions across multiple datasets. This involves adaptively sampling the vibration signals based on the sampling rate of the sensor, incorporating the frequency domain to unify input dimensions, and using a fault-free reference signal as an auxiliary input. To extract features from vibration signals, we first train a fault classification network, then convert and align the extracted features into word embedding, and finally concatenate these with text embedding as input to an LLM. To evaluate the performance of the proposed method, we constructed the first large-scale multimodal bearing health management (MBHM) dataset, including paired vibration signals and textual descriptions. With our unified vibration signal representation, BearLLM using one set of pre-trained weights achieves state-of-the-art performance on nine publicly available fault diagnosis benchmarks, outperforming specific methods designed for individual datasets. We provide a dataset, our model, and code to inspire future research on building more capable industrial multimodal models (https://github.com/hatton613/BearLLM).

  • 5 authors
·
Aug 20, 2024